Inogen One Technical Manual

 
Inogen One Technical Manual 5,0/5 3455 reviews
  1. Inogen One G2 Manual
  2. Inogen One G3 Problems
  3. Inogen One G2 Technical Manual

Technical ManualPN 96-00447-00-04 B0018This manual applies to the following Inogen, Inc. Products:.Inogen One Oxygen Concentrator, model # IO-100 Inogen One AC Power Supply, model # BA-101 Inogen One Lithium Ion Battery, model # BA-100 Inogen One Satellite Conserver, model # SC-100 Inogen One Mobile Power Charger, model # BA-106 Inogen One External Battery Charger with Power Supply, model # BA-103This manual will be updated periodically.

INOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUAL 96-02735-00-01 Revision CCONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 1 of 20This Manual applies to the following Inogen, Inc. Products:CONFIDENTIAL and PROPRIETARY.Inogen One G2 Oxygen Concentrator, model # IO-200.Inogen Universal Power Supply, model # BA-107 & BA-207.Battery, model # BA 200.Battery, model # BA-5-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 2 of 20TABLE OF CONTENTS INFORMATION FOR PROVIDERS OF THE INOGEN ONE G2. 2.3.CAUTION AND WARNING STATEMENTS. 4 SETTING UP A PATIENT ON INOGEN ONE. 62.1.RECOMMENDATIONS FOR USE. 62.2.SYSTEM COMPONENTS. 62.3.USING THE INOGEN ONE G2.

72.4.SELECTING THE PROPER FLOW SETTING. 7SERVICING THE INOGEN ONE G2. 9 3.1.MAINTENANCE BY THE PROVIDER. 93.2.MAINTENANCE BY THE PATIENT. 133.3.EXPECTED SERVICE REQUIREMENTS. 164.INOGEN ONE G2 SYSTEM SPECIFICATIONS. 175.INOGEN ONE G2 ERROR CODE TABLE.

186.CONTACTS FOR MORE INFORMATION. 20CONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 3 of 201. INFORMATION FOR PROVIDERS OF THE INOGEN ONE G2 Thank you for choosing to provide your patients with the Inogen One G2 oxygen concentrator.

We are pleased to offer you and your patients one solution for your many oxygen needs. This Technical Manual will familiarize you with provider-specific information regarding the Inogen One G2 Oxygen Concentrator and its accessories.Before reading this TechnicalManual, please read and review the Inogen One G2 Patient Manual for description andindications for use of the device. Be sure to thoroughly read all of the information in this manual in its entirety. If you have any additional questions, please see the list of contacts at the end of this Technical Manual. Instructions included in this Technical Manual are intended to help assure that patients are given proper guidance in the use and function of the Inogen One G2 and its accessories.

Proper care in relaying this information will not only enhance the user’s experience with the Inogen One G2, but will also protect the patient, prolong the life of the device, and help you avoid unnecessary service calls and complaints from users.1.1. Caution and Warning Statements You will see Warnings and Cautions throughout this Technical Manual. To ensure effective Oxygen Therapy and proper operation of the Inogen One G2 Oxygen Concentrator, you must observe them carefully.

A WARNING indicates that the personal SAFETY of the Patient may be involved. Disregarding a WARNING could result in a significant injury. Be sure that patients WARNINGunderstand all WARNING statements. A CAUTION indicates that a precaution or a service procedure must be followed.CAUTIONDisregarding a caution could lead to a minor injury or damage to the equipment. Be sure that patients understand all CAUTION statements.CONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 4 of 20NOTEA NOTE indicates specific information to improve ease of use or maintenance of the equipment.

A DESIGN NOTE indicates specific information regarding the design of the InogenDESIGN NOTEOne G2 and/or accessories. This information is included in this manual to provide you with a greater working understanding of the device. This information is not required to operate or maintain the Inogen One G2.The Inogen One G2 User Manual contains additional cautions and warnings.CONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 5 of 202. SETTING UP A PATIENT ON INOGEN ONE 2.1. Recommendations for Use The Inogen One G2 Oxygen Concentrator is used on a prescriptive basis by patients requiring supplemental oxygen.

It supplies a high concentration of oxygen and is used with a nasal cannula to channel oxygen from the concentrator to the patient. You may choose to equip your patients with the Inogen One G2 so it may be used in home, institution, vehicle and various mobile environments.

Availability of an alternate source of oxygen is recommended in case of power NOTEoutage. Several certifying bodies for Home Health Care Providers require that back-up oxygen be available to the patient. Supplemental oxygen cylinders or extra Inogen One G2 Batteries may satisfy these requirements.Oxygen demand of some patients, particularly those with high breathing rates CAUTIONand high flow settings, may exceed the capabilities of the Inogen One G2. Inogen suggests that each patient be titrated to assure that the Inogen One G2 is an appropriate solution for their needs.2.2. System Components The following are standard components of the Inogen One system: o Inogen One G2 Oxygen Concentrator o 12 cell Battery o AC/DC Power Supply o Cart o Carry Bag o Cannula Patient Set-Up. To properly set up a patient on the Inogen One G2 System, you may need to provide: o Pulse Oximeter (for titration, not included) CONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 6 of 20o Extra cannulas (not included) 2.3.

Using the Inogen One G2 To quickly configure the Inogen One G2 for patient use: 1. Slide the battery onto the bottom of the system until the latch clicks into place. Connect AC or DC power cord to the power supply. Connect the power supply to the Inogen One G2. Plug into closest AC or DC outlet. Turn on the Inogen One G2 by pressing the on/off button.

Inogen One G2 Manual

Set the Inogen One G2 to correct flow setting prescribed by the physician or clinician by pressing the + (increase flow) or – (decrease flow) button. Attach cannula to the metal hose barb located next to the handle of the Inogen One G2. For further information regarding the use of the Inogen One G2, please consult the User Manual. Selecting the Proper Flow Setting 2.4.1.

Inogen One G3 Problems

Bolus Volumes Specification All oxygen conserving devices (OCD’s) function differently, and therefore it is prudent to titrate patients for any new conserving device. Delivery timing, bolus volume, and oxygen concentration all contribute to a patient’s fraction of inspired oxygen (FiO2), and therefore to the OCD’s efficacy at maintaining the patient’s blood oxygen saturation. As an oxygen concentrator, the Inogen One G2 does not contain a finite stored volume of oxygen, such as with compressed gas or liquid cryogenic systems. The Inogen One G2 can provide oxygen to the patient as long as a source of electricity is available. However, because the oxygen is being produced as it is used, supply of oxygen is rate-limited. The Inogen One G2 delivers up to 900 ml/min of 90% oxygen. At each flow setting, the Inogen One generates a specific amount of oxygen (180ml per setting), and the on-board OCD attempts to deliver all of this product to the patient.

Inogen One Technical Manual

Inogen One G2 Technical Manual

This is equivalent to a conserving ratio of 5.6 at all flow settings and breathing rates. CONFIDENTIAL and PROPRIETARY96-02735-00-01 revCINOGEN ONE G2 OXYGEN CONCENTRATOR TECHNICAL MANUALPage 7 of 20Slower breathing patients will receive larger boluses, and faster breathing patients will receive smaller boluses. This method of bolus volume determination is similar to what is experienced by a DESIGN NOTEpatient using a continuous flow concentrator – actual alveolar oxygen inspiration is more closely linked to flow setting than to breathing rate.In general, the Inogen One G2 delivers 12ml per bolus per flow setting at 15 breaths per minute (180ml/min per flow setting).